Connection Guide Refresh

CPE Configuration Guide

To connect your devices to this ACS, use the following global settings. Most devices will have a "TR-069" or "CWMP" section in their management interface.

http://acs.realcode.co.ke/acs
Enabled (300-3600s)

Vendor Specific Examples

TP-Link / Mercusys

Navigate to: Advanced > System Tools > CWMP Settings

  • CWMP: Enable
  • Inform: Enable
  • Inform Interval: 300
  • ACS URL: http://acs.realcode.co.ke/acs
Huawei (ONT)

Navigate to: System Tools > TR-069

  • ACS URL: http://acs.realcode.co.ke/acs
  • Periodic Inform: Enable
  • Inform Interval: 3600

Debugging Tips

  • Firewall: Ensure the CPE can reach the ACS server on port 80/443.
  • Connection Request: If the ACS cannot trigger the CPE, check the CPE's Firewall and ensure NAT mapping is correct.
  • DNS: If using a hostname, ensure the CPE can resolve it.